Hardware
4.
Make the desired DIP switch settings.
5.
Replace the back cover.
1.2.2 Serial Mode DIP Switch Settings
DIP switch 5 is used to set COM A and COM B in RS232 or RS485 mode.
Mode DIP switch 5
RS485 ON
RS232 (default) OFF
1.2.3 Monitor Address DIP Switch Settings
DIP swi tches 1 –4 a re used to set the monitor addresses.
Address DIP switch 1 DIP switch 2 DIP switch 3 DIP switch 4
0 OFF OFF OFF OFF
1 ON OFF OFF OFF
2 OFF ON OFF OFF
3ONONOFFOFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7ONONONOFF
8 OFF OFF OFF ON
9ONOFFOFFON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14OFFONONON
15 ON ON ON ON
1.2.4 Example
12345
This example sets the address to 5 and the mode to RS232.