Fault T racing
TheiXPanelK100isworking,butoneormorekeys
arenotworking
1.
Check that the flex cables are correctly fitted.
2.
Replace the front according to the Replacing the Rear Cover section.
Linesindisplayhaswrongcolororthedisplaypicture
isshifted
1.
Check if the display has a wide vertical or horizontal area across the
display. It should be at least 2-3 cm wide with a grey or black color. See
Replacing the Display/Display Cable for ins tructions on how to correct this.
2.
Make sure the display cable is correctly fitted.
3.
Make sure the display cable is not folded or damaged in any way. Replace the
display cable according to the Replacing the Display/Display Cable section.
Lowbattery/Nobattery
1.
Connect iX Panel K100 to an external power source to automatically charge
the battery.
BeijerElectronics, MAEN003