Seite 1 - SCOM Protocol on RBC

SCOM Protocol on RBCManualMAEN993, 2009-12English

Seite 2 - Foreword

Protocol Description and Timings10 Beijer Electronics, MAEN993Conditions for Response MessageThe conditions for a response message generated by the Be

Seite 3 - Contents

Protocol Description and TimingsBeijer Electronics, MAEN993 11The Lr value depends on the command, for which the response message is generated. Detail

Seite 4

Protocol Description and Timings12 Beijer Electronics, MAEN993

Seite 5 - 1 Interface Configuration

Command ReferenceBeijer Electronics, MAEN993 135 Command ReferenceThe Lauer SCOM protocol exposes many commands for remote control of a Beijer Electro

Seite 6 - SCOM Message Basic Format

Command Reference14 Beijer Electronics, MAEN9935.1 BRT Backlight BrightnessSets the backlight level to the given value. This command affects only the

Seite 7 - Beijer Electronics, MAEN993 7

Command ReferenceBeijer Electronics, MAEN993 15Example 1Set the backlight level of device at address 0.7 (group 0, address 7) to 130 (0x82):Device at

Seite 8 - 3 Device Addressing

Command Reference16 Beijer Electronics, MAEN9935.2 MAN Manufacturer IDRequests the manufacturer ID from the device. The manufacturer ID is a short, ma

Seite 9 - Beijer Electronics, MAEN993 9

Command ReferenceBeijer Electronics, MAEN993 175.3 VER Unit ID and Model / Version NumberRequests the preassigned unit ID and model code, and the vers

Seite 10 - Delayed Response

Command Reference18 Beijer Electronics, MAEN9935.4 POT Local ControlEnables or disables the local backlight level control. If the local backlight cont

Seite 11 - Command Reference

Command ReferenceBeijer Electronics, MAEN993 19Maximum Lr for this Command9Example 1Disable the local control of device at address 0.7 (group 0, addre

Seite 12

ForewordBeijer Electronics, MAEN993SCOM Protocol on RBCForewordThe Lauer SCOM Protocol is designed for controlling different Beijer Electronics device

Seite 13 - 5 Command Reference

Command Reference20 Beijer Electronics, MAEN9935.5 TYPUnit Type and Model NumberQueries the device type and model.Supported since Firmware VersionLAUE

Seite 14 - 5.1 BRT

Command ReferenceBeijer Electronics, MAEN993 215.6 LAULauer ExtensionThe Lauer Extension is a new SCOM command specially developed for Beijer Elec-tro

Seite 15

Command Reference22 Beijer Electronics, MAEN993Response Message (Acknowledge)The following sections describe all supported LAU sub-commands in each fu

Seite 16 - 5.2 MAN

Command ReferenceBeijer Electronics, MAEN993 235.6.1 LAU_CONFIG_GETFWVERSION (0x0101)Firmware VersionReturns the current firmware name and version inc

Seite 17 - 5.3 VER

Command Reference24 Beijer Electronics, MAEN9935.6.2 LAU_CONFIG_GETMANUFACTURER (0x010C)ManufacturerRequests the manufacturer ID from the device. The

Seite 18 - 5.4 POT

Command ReferenceBeijer Electronics, MAEN993 255.6.3 LAU_CONFIG_GETDEVICENAME (0x010D)Device NameReturns the device type and model. Actually, this com

Seite 19

Command Reference26 Beijer Electronics, MAEN9935.6.4 LAU_CONFIG_GETDILMODE (0x010E)DIL Switch ModeFor a base configuration, Beijer Electronics RBCs ar

Seite 20 - Unit Type and Model Number

Command ReferenceBeijer Electronics, MAEN993 275.6.5 LAU_CONFIG_GETDISPLAYADR (0x010F)Device AddressReturns the software configured device address. Th

Seite 21 - Lauer Extension

Command Reference28 Beijer Electronics, MAEN9935.6.6 LAU_CONFIG_GETCOMSERMODE (0x0110)SCOM Serial Interface ModeThe serial interface mode indicates th

Seite 22

Command ReferenceBeijer Electronics, MAEN993 295.6.7 LAU_CONFIG_GETPOTMODE (0x0113)POT ModeReturns the local backlight level control configuration. If

Seite 23 - Firmware Version

ContentsBeijer Electronics, MAEN993 IContents1 Interface Configuration 52 Message Format and Description 63 Device Addressing 84 Protocol Description

Seite 24 - Manufacturer

Command Reference30 Beijer Electronics, MAEN9935.6.8 LAU_CONFIG_GETREMOTECONTROL (0x011C)Remote Control ConfigurationThis command returns the configur

Seite 25 - Device Name

Command ReferenceBeijer Electronics, MAEN993 315.6.9 LAU_CONFIG_GETSTARTUPBRIGHTNESSMODE (0x0124)Startup Brightness ModeThe Beijer Electronics RBCs ca

Seite 26 - DIL Switch Mode

Command Reference32 Beijer Electronics, MAEN993Example Check which mode the backlight of the device at address 0.7 (group 0, address 7) has at startup

Seite 27 - Device Address

Command ReferenceBeijer Electronics, MAEN993 335.6.10LAU_CONFIG_GETSERIALNUMBER (0x0125)Serial NumberReturns the serial number of the device.Supported

Seite 28 - SCOM Serial Interface Mode

Command Reference34 Beijer Electronics, MAEN9935.6.11LAU_CONFIG_GETDEFAULTBRIGHTNESS (0x0126)Startup Brightness ModeFor the Beijer Electronics RBCs a

Seite 29 - POT Mode

Command ReferenceBeijer Electronics, MAEN993 355.6.12LAU_CONFIG_GETDISPLAYGROUP (0x0127)Device GroupBesides the standard addressing scheme, where the

Seite 30 - Remote Control Configuration

Command Reference36 Beijer Electronics, MAEN9935.6.13LAU_CONFIG_GETKEYPRESSMODE (0x012A)Keypress ModeThe brightness of the Beijer Electronics RBCs can

Seite 31 - Startup Brightness Mode

Command ReferenceBeijer Electronics, MAEN993 37Example Check the keypress mode of the device at address 0.3 (group 0, address 3):According to the data

Seite 32

Command Reference38 Beijer Electronics, MAEN9935.6.14LAU_CONFIG_SETDILMODE (0x018E)DIL Switch ModeFor a base configuration, Beijer Electronics RBCs ar

Seite 33 - Serial Number

Command ReferenceBeijer Electronics, MAEN993 39Example Set the device at address 0.7 (group 0, address 7) in the mode to override the DIL settings (i.

Seite 34 - (0x0126)

ContentsII Beijer Electronics, MAEN9935.6.27 LAU_STATUS_POTMODE (0x0304) . . . . . . . . . . . . . . . . . . . . . .615.6.28 LAU_STATUS_BUZZER (0x0306

Seite 35 - Device Group

Command Reference40 Beijer Electronics, MAEN9935.6.15LAU_CONFIG_SETDISPLAYADR (0x018F)Device AddressStores a software address of a device in the inter

Seite 36 - Keypress Mode

Command ReferenceBeijer Electronics, MAEN993 41Example Set the software configured device address (excluding group) from the device at ad-dress 14.7 (

Seite 37 - Example

Command Reference42 Beijer Electronics, MAEN9935.6.16LAU_CONFIG_SETCOMSERMODE (0x0110)SCOM Serial Interface ModeThe serial interface mode indicates th

Seite 38

Command ReferenceBeijer Electronics, MAEN993 43Response Message (Negative Acknowledge)Under normal operation conditions, a device never sends a negati

Seite 39

Command Reference44 Beijer Electronics, MAEN9935.6.17LAU_CONFIG_SETREMOTECONTROL (0x019C)Remote Control ConfigurationThis command returns a configurat

Seite 40

Command ReferenceBeijer Electronics, MAEN993 45Example Check if the device at address 0.7 (group 0, address 7) is configured to remote control other d

Seite 41

Command Reference46 Beijer Electronics, MAEN9935.6.18LAU_CONFIG_SETSTARTUPBRIGHTNESS MODE (0x01A4)Startup Brightness ModeThe Beijer Electronics RBCs c

Seite 42

Command ReferenceBeijer Electronics, MAEN993 47Response Message (Negative Acknowledge)Under normal operation conditions, a device never sends a negati

Seite 43 - 0 1 2 3 4 5 6 7 8

Command Reference48 Beijer Electronics, MAEN9935.6.19LAU_CONFIG_SETSERIALNUMBER (0x01A5)Serial NumberSets the serial number of the device. This functi

Seite 44 - (0x019C)

Command ReferenceBeijer Electronics, MAEN993 495.6.20LAU_CONFIG_SETDEFAULTBRIGHTNESS (0x01A6)Default BrightnessA default brightness can be stored for

Seite 45

Interface ConfigurationBeijer Electronics, MAEN993 51 Interface Configuration A command can be sent either using the serial interface (RS232 or RS485)

Seite 46 - MODE (0x01A4)

Command Reference50 Beijer Electronics, MAEN993Maximum Lr for this Command9Example Set the default brightness of the device at address 0.7 (group 0, a

Seite 47

Command ReferenceBeijer Electronics, MAEN993 515.6.21LAU_CONFIG_SETDISPLAYGROUP (0x01A7)Device GroupBesides the standard addressing scheme, where the

Seite 48 - (0x01A5)

Command Reference52 Beijer Electronics, MAEN993Example Write the new display group to the device at address 14.7 (group 14, address 7), which is effec

Seite 49 - Default Brightness

Command ReferenceBeijer Electronics, MAEN993 535.6.22LAU_CONFIG_SETKEYPRESSMODE (0x01AA)Keypress ModeThe brightness of the Beijer Electronics RBCs can

Seite 50 - 0x07 0x07

Command Reference54 Beijer Electronics, MAEN993Response Message (Acknowledge)Response Message (Negative Acknowledge)Under normal operation conditions,

Seite 51 - (0x01A7)

Command ReferenceBeijer Electronics, MAEN993 555.6.23LAU_CONTROL_BUZZER (0x0202)Buzzer ControlActivates the built-in buzzer, if available.Supported si

Seite 52

Command Reference56 Beijer Electronics, MAEN993Example Enable the buzzer of the device at address 0.7 (group 0, address 7):The device at address 0.7 (

Seite 53 - (0x01AA)

Command ReferenceBeijer Electronics, MAEN993 575.6.24LAU_CONTROL_RESET (0x0207)Software ResetThis commands resets the software. All software initializ

Seite 54

Command Reference58 Beijer Electronics, MAEN9935.6.25LAU_STATUS_DISPLAYADR (0x0302)Current Device AddressReturns the current device address. If the DI

Seite 55 - Buzzer Control

Command ReferenceBeijer Electronics, MAEN993 595.6.26LAU_STATUS_SCOMSERMODE (0x0303)Current SCOM Serial Interface ModeThe serial interface mode indica

Seite 56

Message Format and Description6 Beijer Electronics, MAEN9932 Message Format and DescriptionAn SCOM message is a stream of bytes, containing the destin

Seite 57 - Software Reset

Command Reference60 Beijer Electronics, MAEN993Example Read the current serial interface mode of the device at address 0.7 (group 0, address 7):Accord

Seite 58 - Current Device Address

Command ReferenceBeijer Electronics, MAEN993 615.6.27LAU_STATUS_POTMODE (0x0304)Current POT ModeMost of our devices have a potentiometer or two button

Seite 59

Command Reference62 Beijer Electronics, MAEN9935.6.28LAU_STATUS_BUZZER (0x0306)Current Buzzer StateReturns the current buzzer state. The buzzer state

Seite 60

Command ReferenceBeijer Electronics, MAEN993 635.6.29LAU_STATUS_BACKLIGHT (0x0307)Current Backlight StateReturns the current backlight level value.Sup

Seite 61 - Current POT Mode

HEAD OFFICESWEDENBeijer Electronics Products ABBox 426SE-201 24 Malmö, SwedenTel: +46 40 35 86 00Fax: +46 40 93 23 [email protected]

Seite 62 - Current Buzzer State

Message Format and DescriptionBeijer Electronics, MAEN993 7As shown in the table, the DATA field is optional. If the message does not require any data

Seite 63 - Current Backlight State

Device Addressing8 Beijer Electronics, MAEN9933 Device Addressing By default, a Beijer Electronics RBC supports the standard SCOM addressing scheme, w

Seite 64

Protocol Description and TimingsBeijer Electronics, MAEN993 94 Protocol Description and TimingsThe protocol used for transferring SCOM messages and re